DUST GASKET AND FIXING RING FOR LASER TRACKBALL by GE Healthcare
Platform Price
Contact for Price
The Dust Gasket and Fixing Ring for the Laser Trackball by GE Healthcare is essential for maintaining the Vivid E9 ultrasound system. Designed for easy attachment and removal, it offers high-temperature resistance and excellent durability against various chemicals, ensuring optimal performance and longevity of the trackball assembly while preventing dust entry and overheating. The Dust Gasket and Fixing Ring for Laser Trackball kit consists of rubber type dust gasket and trackball fixing ring. The laser trackball is an advance cursor control device, which is a part of Vivid E9 operating panel. As this works on the laser, the integrated circuit with optics take continual snapshot of ball surface and how the features in these snapshots move is used to detect ball motion. A gasket and a fixing ring is used to fix the trackball in the operating panel. The gasket is used to fill the space between two parts or considered as a sealing agent. The shape and size of the gasket varies according to the requirement. The rubber gasket is used in trackball assembly to avoid dust entries as well, thus helps to increase the lifespan of the trackball and prevent it from over heating. It works in a temperature range of 54° C to 150° C. A trackball fixing ring is provided to add more space between trackball and operator panel bezel. This kit is available as a spare part, thus the unit be replaced whenever required.
Specifications
- Models
- VIVID E9
- Features
- Spare part - can be attached and removed easily; High temperature resistance; Resistance to oxygen, ozone, sunlight, acid , oil, grease and ethanol; Odor free; Stable color; Good chemical resistance; Low electrical conductivity; Abrasion resistant
SKU: O16880-GA200971
Part Number: GA200971
Status:In Stock
Supported Models
Key Highlights
- Durable Construction: The DUST GASKET AND FIXING RING is designed with high-temperature resistance, ensuring reliable performance in demanding environments, which is critical for maintaining optimal functionality in medical imaging applications.
- Enhanced Longevity: This spare part effectively prevents dust ingress, thereby increasing the lifespan of the laser trackball and minimizing the need for frequent replacements, which is essential for maintaining operational efficiency.
- Chemical Resistance: With resistance to various substances including acids, oils, and ethanol, this gasket and ring provide robust protection, ensuring that the components remain functional under a variety of conditions.
- User-Friendly Installation: Designed for easy attachment and removal, this product facilitates quick maintenance, allowing biomedical engineers and hospital staff to perform repairs with minimal downtime.
- Stable Performance: The gasket maintains its color and integrity over time, ensuring that aesthetic and functional qualities are preserved, which is important for maintaining the professional appearance of medical equipment.
Compatible Systems & Use Cases
- Models: VIVID E9
- Use Cases: This product is particularly suited for use in ultrasound imaging systems, specifically in environments where precision and reliability are paramount. It is ideal for hospitals and clinics that utilize the VIVID E9 system for diagnostic imaging, ensuring that the trackball operates smoothly and efficiently.
Technical Specifications
| Parameter | Value |
|---|---|
| Temperature Range | -54° C to 150° C |
| Material | Rubber |
| Resistance Properties | High chemical resistance, abrasion resistant, low electrical conductivity |
Clinical and Service Value
The DUST GASKET AND FIXING RING for the laser trackball is an essential component for maintaining the operational integrity of the VIVID E9 ultrasound system. By preventing dust and debris from entering the trackball assembly, this product not only extends the lifespan of the trackball but also enhances the overall performance of the ultrasound system. This is crucial for healthcare providers who rely on consistent and accurate imaging for patient diagnosis and treatment.
From a maintenance perspective, the ease of installation and removal of this spare part significantly reduces downtime during servicing. Biomedical engineers can swiftly replace the gasket and fixing ring as needed, ensuring that the ultrasound systems remain operational and that patient care is not compromised. This streamlined maintenance process ultimately contributes to improved workflow efficiency in clinical settings, allowing healthcare professionals to focus on delivering quality care without the interruptions caused by equipment malfunctions.
Additional notes
The Dust Gasket and Fixing Ring for Laser Trackball kit consists of rubber type dust gasket and trackball fixing ring. The laser trackball is an advance cursor control device, which is a part of Vivid E9 operating panel. As this works on the laser, the integrated circuit with optics take continual snapshot of ball surface and how the features in these snapshots move is used to detect ball motion. A gasket and a fixing ring is used to fix the trackball in the operating panel. The gasket is used to fill the space between two parts or considered as a sealing agent. The shape and size of the gasket varies according to the requirement. The rubber gasket is used in trackball assembly to avoid dust entries as well, thus helps to increase the lifespan of the trackball and prevent it from over-heating. It works in a temperature range of -54° C to 150° C. A trackball fixing ring is provided to add more space between trackball and operator panel bezel. This kit is available as a spare part, thus the unit be replaced whenever required.
Interested in this product?
Get detailed information, pricing, and availability for DUST GASKET AND FIXING RING FOR LASER TRACKBALL by GE Healthcare. Our team will respond to your inquiry within 24 hours.
Inquire about DUST GASKET AND FIXING RING FOR LASER TRACKBALL by GE Healthcare
Fill out the form below and we'll get back to you as soon as possible.
Related Products

FRU NEW FASTLINK ADAPTER FOR IB WITH NATIVE DL8 by GE Healthcare
Key Highlights Enhanced Connectivity : The FRU New FastLink Adapter is designed to seamlessly integrate with GE Healthcare imaging systems, facilitating effici…
SKU: O16880-5461627
Part Number: 5461627

JEDI HV TANK VASC__SPARE by GE Healthcare
Key Highlights Robust Design : The JEDI HV Tank VASC by GE Healthcare is engineered for durability and reliability, ensuring optimal performance in high demand…
SKU: O16880-2340595
Part Number: 2340595

ELECTRONIC BOARD CONTROLLING COLLIMATOR CANOPEN BUS V2 by GE Healthcare
Key Highlights Advanced Control : The Electronic Board controlling the Collimator Canopen Bus V2 by GE Healthcare enhances the precision and efficiency of imag…
SKU: O16880-51276092
Part Number: 5127609-2

FRU: CAB00110_02 by GE Healthcare
Product Brief: FRU: CAB00110 02 by GE Healthcare Key Highlights Brand Reliability : GE Healthcare is a trusted name in the medical device industry, known for i…
SKU: O16880-5748784
Part Number: 5748784