Reliable Medical Imaging Solutions: Repair, Maintenance & Parts
[email protected]Whatsapp:008618816788897
TRANSDUCER, 20.3MM SIZE, 90° FIELD OF VIEW, SECTOR PHASED ARRAY FORM FACTOR, 2 TO 4MHZ FREQUENCY RANGE, 80 NUMBER OF ELEMENTS, S4-2 SERIES, by Philips placeholder image

TRANSDUCER, 20.3MM SIZE, 90° FIELD OF VIEW, SECTOR PHASED ARRAY FORM FACTOR, 2 TO 4MHZ FREQUENCY RANGE, 80 NUMBER OF ELEMENTS, S4-2 SERIES, by Philips

Philips

OEM List Price

$10,915.00

Platform Price

Contact for Price

The Philips S4-2 transducer features a 20.3mm size and a 90° field of view, operating within a frequency range of 2 to 4MHz. Its sector phased array form factor and 80 elements make it ideal for high-resolution imaging in systems like ENVISOR and HDI 5000, enhancing diagnostic capabilities in ultrasound applications. TRANSDUCER, 20.3MM SIZE, 90° FIELD OF VIEW, SECTOR PHASED ARRAY FORM FACTOR, 2 TO 4MHZ FREQUENCY RANGE, 80 NUMBER OF ELEMENTS, S4 2 SERIES, by Philips

Specifications

Models
ENVISOR, ENVISOR HD, HDI 5000

SKU: O18539-453561270622

Part Number: 453561270622

Status:In Stock

Supported Models

ENVISORENVISOR HDHDI 5000

Key Highlights

  • Advanced Imaging Technology: The Philips S4-2 transducer features a 90° field of view, providing enhanced imaging capabilities for a variety of ultrasound applications. This wide angle allows for comprehensive visualization of anatomical structures.
  • Optimized Frequency Range: Operating within a frequency range of 2 to 4 MHz, this transducer is designed to deliver high-resolution images while effectively penetrating tissue, making it suitable for both superficial and deeper examinations.
  • Sector Phased Array Design: The phased array form factor of the transducer allows for improved sensitivity and versatility, enabling it to perform well in various clinical settings, including cardiology and obstetrics.
  • High Element Count: With 80 elements, this transducer ensures detailed imaging, facilitating accurate diagnostics and assessments, which is crucial in patient care.
  • Compatibility with Leading Models: Designed for seamless integration, the S4-2 series transducer is compatible with Philips ENVISOR, ENVISOR HD, and HDI 5000 ultrasound systems, enhancing existing imaging capabilities.

Compatible Systems & Use Cases

  • Models:
    • ENVISOR
    • ENVISOR HD
    • HDI 5000
  • Use Cases:
    • Cardiac imaging
    • Obstetric and gynecological assessments
    • General abdominal imaging
    • Vascular studies

Technical Specifications

ParameterValue
Size20.3 mm
Field of View90°
Frequency Range2 to 4 MHz
Number of Elements80
Form FactorSector Phased Array

Clinical and Service Value

The Philips S4-2 transducer enhances clinical workflows by providing high-quality imaging essential for accurate diagnostics. Its compatibility with multiple ultrasound systems allows healthcare facilities to maximize their existing investments in imaging technology without the need for extensive upgrades. This transducer's advanced features support a wide range of applications, ensuring that clinicians can deliver comprehensive care across various specialties.

In terms of maintenance and service, the robust design of the S4-2 series transducer ensures durability and reliability, minimizing downtime and enhancing operational efficiency. Regular maintenance protocols can be easily established, supported by Philips' commitment to quality and service. This transducer not only improves imaging capabilities but also streamlines workflows, allowing healthcare providers to focus on patient outcomes rather than equipment issues.

Additional notes

TRANSDUCER, 20.3MM SIZE, 90° FIELD OF VIEW, SECTOR PHASED ARRAY FORM FACTOR, 2 TO 4MHZ FREQUENCY RANGE, 80 NUMBER OF ELEMENTS, S4-2 SERIES, by Philips

Interested in this product?

Get detailed information, pricing, and availability for TRANSDUCER, 20.3MM SIZE, 90° FIELD OF VIEW, SECTOR PHASED ARRAY FORM FACTOR, 2 TO 4MHZ FREQUENCY RANGE, 80 NUMBER OF ELEMENTS, S4-2 SERIES, by Philips. Our team will respond to your inquiry within 24 hours.

Free consultation and quote
Expert technical support
Custom configuration available
24-hour response guarantee

Inquire about TRANSDUCER, 20.3MM SIZE, 90° FIELD OF VIEW, SECTOR PHASED ARRAY FORM FACTOR, 2 TO 4MHZ FREQUENCY RANGE, 80 NUMBER OF ELEMENTS, S4-2 SERIES, by Philips

Fill out the form below and we'll get back to you as soon as possible.

By submitting this form, you agree to our privacy policy. We will only use your information to respond to your inquiry.

Related Products

BUSH by Philips

BUSH by Philips

Philips

Product Brief: BUSH by Philips Key Highlights Innovative Design : The BUSH by Philips is engineered to enhance imaging capabilities, ensuring high quality diag…

SKU: O18539-451291768082

Part Number: 451291768082

OEM List Price$279.00Platform PriceContact for Price
Learn More
CONTROL PANEL ELECTRONICS ASSEMBLY, PATH by Philips

CONTROL PANEL ELECTRONICS ASSEMBLY, PATH by Philips

Philips

Product Brief: CONTROL PANEL ELECTRONICS ASSEMBLY, PATH by Philips Key Highlights Enhanced Functionality : The CONTROL PANEL ELECTRONICS ASSEMBLY is designed t…

SKU: O18539-453561360221

Part Number: 453561360221

Platform PriceContact for Price
Learn More
ADAPTER,AC/DC,19V,2.9A,75W, VISIQ by Philips

ADAPTER,AC/DC,19V,2.9A,75W, VISIQ by Philips

Philips

Product Brief: ADAPTER, AC/DC, 19V, 2.9A, 75W, VISIQ by Philips Key Highlights Reliable Power Supply : The Philips VISIQ adapter provides a stable 19V output w…

SKU: O18539-453561815861

Part Number: 453561815861

OEM List Price$1,026.00Platform PriceContact for Price
Learn More
TOUCHSCREEN REAR ENCLOSURE ASSEMBLY by Philips

TOUCHSCREEN REAR ENCLOSURE ASSEMBLY by Philips

Philips

Key Highlights Enhanced Durability : The Philips Touchscreen Rear Enclosure Assembly is designed to provide robust protection for sensitive components, ensurin…

SKU: O18539-453561442082

Part Number: 453561442082

OEM List Price$51.00Platform PriceContact for Price
Learn More